Gas Meter S-type

| Model NO. | SA25MT-ULS | SA25MT-XLS | |||
| Gas Meter | Authorization Expiry Period | 10 years | |||
| Max. Flow Rate | 2.5 m3/h | ||||
| Connector Specifications | Piping | 15 A or 20 A (Depending on connector) | |||
| Spacing Between In & Out |
90 mm | 130 mm | |||
| Connection Diameter | M36 × 2 | ||||
| Inflow Direction | left | ||||
| Micro computer Controller | Security Functions | Shutdown | Excess/Increased flow, Preset usage time (a la carte response), Low battery voltage, Voltage alarm detection, Security confirmation leakage after restoration, Test , Seismic sensor, Pressure drop, Gas detector, Remote sensor 1 | ||
| Alert | Leakage detection by micro flow, Low battery voltage, Shutdown fialure, Leakage detection by micro pressure drop, Abnormal setting pressure, Abnormal lock-up pressure | ||||
| Display Function |
LCD | Shutdown, Alert, Shutdown area, Auto setting, etc. | |||
| LED | Shutdown, Leakage detection by micro flow, Shutdown failure | ||||
| Communications functions | Security Functions | Shutdown, Alert, Usage time shutoff notice, Call out to shutoff valve restoration, etc., Detailed shutdown data, Leak detection by micro flow timer, Test call, etc. | |||
| Type of Signal |
Communications (N and H lines): KHK common e-script, Gas detector, Remote sensor 1 and 2, Remote opening and closing: Non-voltage contacts
|
||||
| Power Supply | Lithium Battery | ||||
| Working Temperature | – 30 ℃ – 60 ℃ | ||||
| Standard Painting Color | Light gray equivalent to Muncell 5Y7.5/1 | ||||
| Weight | 2.0kg | 2.0kg | |||
| Price | – | – | |||
| Drawings | CAD | Performance curve | Maunal | Product picture | |
| SA25MT-ULS | |||||
| SA25MT-XLS |
E4・EB-Type Gas-meter
|
![]() |
| E4-Type | EB-Type |
| Model No. | EY4MT-ZL | EY4MT-YL | EBY6 | EBY10 | EBY16 | ||
| Gas Meter | Authorization Expiry Period | 10 years | |||||
| Max. Flow Rate | 4.0 m3/h | 6.0 m3/h | 10 m3/h | 16 m3/h | |||
| Connector Specifications | Piping | 20 A (Depending on connector) | |||||
| Spacing Between In & Out |
90 mm | 130 mm | 220 mm | ||||
| Connection Diameter | M36 × 2 | M56 × 2 | M64 × 2 | ||||
| Inflow Direction | left | ||||||
| Micro computer Controller | Security Functions | Shutdown | Excess / Increased flow, Preset usage time, Security confirmation leakage after restoration | Excess / Increased flow, Security confirmation leakage after restoration | |||
| Shutdown / Other | Seismic sensor, Pressure drop,Gas detector, External Equipment Coordinate, Test, Low battery voltage, Center, In emergency, Prepay *1, Expiry date | ||||||
| Alert | Leakage detection by micro flow, Low battery voltage, Shutdown failure, Leakage detection by micro pressure drop, Abnormal setting pressure, Abnormal lock-up pressure, Prepay *1, Expiry date, Reverse flow, Plug pulled out |
||||||
| Type of Signal | Display Function |
1.Pilot Flame Registering 2.Operating state of Auto setting 3.Shutdown area of Increased flow 4.Usage time shutdown value Status 5.Shutdown 6.Alert |
1.Pilot Flame Registering 2.Operating state of Auto setting 3.Shutdown area of Increased flow 4.Shutdown 5.Alert |
||||
| Communications System | Half-duplex communication System | ||||||
| Pulse signal | 1 L・10 L・100 L/Pulse Switching System | – | |||||
| Power Supply | Lithium Battery(DC3V) | ||||||
| Standard Painting Color | Light Gray | ||||||
| Dimensions | H 140 × W 174 × D 107.5(mm) | H 147 × W 200× D 118.5(mm) |
H 231 × W 299 × D 142(mm) | ||||
| Weight | Approx. 2 kg | Approx. 4.4 kg | |||||
| Price | – | – | – | – | – | ||
※ 1 EBY10,EBY16 are not included.
Microcomputer meter: SB‐type
![]() |
| SB-Type |
| Model No. | SBA4-1 | SBA6-1 | SBA10-1 | SBAL10-1 | SBA16-1 | |||
| Gas Meter | Authorization Expiry Period | 10 years | 7 years | |||||
| Max. Flow Rate | 4 m3/h | 6 m3/h | 10 m3/h | 16 m3/h | ||||
| Connector Specifications | Piping | 20 A | 32 A | 40 A | ||||
| Spacing Between- In & Out |
130 mm | 220 mm | ||||||
| Connection Diameter | M34 × 1.5 W 36.3 11.5 cam/inch |
M34 × 1.5 W36.3 11.5 cam/inch |
M56 × 2 | M64 × 2 | ||||
| Micro Computer Controller | Security Functions | Shutdown | Excess/Increased flow, Security confirmation leakage after restoration, Voltage alarm detection, Test , Gas detector, Seismic sensor, Pressure drop, Remote sensor 1 , Detector disconnected detection, Usage time shutoff (Available SBA4 only), Low battery voltage | |||||
| Alert | Leakage detection by micro flow, Low battery voltage, Shutdown failure, Leak detection by micro pressure, Abnormal setting pressure, Abnormal lock-up pressure | |||||||
| Display Function |
LCD | Shutdown, Alert, Shutdown area, Auto setting, etc. | ||||||
| LED (single aspect) |
Shutdown, Leakage detection by micro flow, Shutdown failure | |||||||
| Communications functions (Built in as standard) |
Security | Shutdown, Alert, Call out to shutoff valve restoration, etc., Detailed shutdown data, Leak detection by micro flow timer, Test call, etc. | ||||||
| Type of Signal | Communications: KHK common e-script Gas detector, Remote sensor 1 and 2, Remote opening and closing: Non-voltage contacts | |||||||
| Power Supply | Lithium battery | |||||||
| Atmospheric Temperature Range | – 30 ℃ – 60 ℃ | |||||||
| Standard Painting Color | White (JPMA R4‐383) | |||||||
| Weight | 5.1 kg | 6.7 kg | 11.6 kg | |||||
| Price | – | |||||||
| Drawing | CAD | Performance curve | Manual | product Photos | |
| SBA4-1 | |||||
| SBA6-1 | ○ | ||||
| SBA10-1 | |||||
| SBAL10-1 | |||||
| SBAL16-1 |
Gas-meter with a built-in shutoff valve:NV‐type
![]() |
| NV‐type |
Note: Three types (Generally separated by region). T: Tokyo dies; O: Osaka dies; N: Nagoya dies |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||

| Drawing | CAD | Performance curve | Manual | product Photos | |
| NV25 | |||||
| NV40 |
※各ファイルは右クリック「名前をつけて保存」からダウンロードして下さい